HA7net+iButton: "Internal DS2417 is not responding" and "Short Detected on 1-wire Bus"

Got these messages when I placed an iButton (DS1990R) on a simple magnetic  probe (ML9092).

The cause? Ground and Data reversed on the probe - Ground at the edge, data in the centre.